Direction For use :
- 1. Take 25 ml of water sample to be tested in the Test jar
- 2. Add 1 micro spoon full of Reagent RX-TH-1.
- 3. Mix contents well to dissolve.
- 4. Add 15 drops of Reagent RX-TH-2 and mix well.
- 5. If colour turns blue, it indicates there is no hardness in the water.
- 6. If colour turns red, it indicates there is hardness.
- 7. Now drop wise add Reagent RX-TH-3 , counting the number of drops while
Mixing until the colour changes from RED to BLUE.
Reagent RX-TH-4 instead of Reagent RX-TH-3
Calculation :
Hardness PPM = RX-TH-3 Number of Drop X 2
Hardness PPM = RX-TH-4 Number of Drop X 5
RX MARINE INTERNATIONAL is most popular chemicals source in INDIA, Keeping ready stock at 5 LOCATION which includes Mumbai, Kandla - Gandhidham, Vizag - Visakhapatnam, Ennore - Chennai, Kolkata more then 3000 types of chemicals. Please click here to get PRODUCT Categories details http://rxmarine.com/Products
Mail Us for any PRODUCT related information and purchase inquiry : rxmarinechemical@gmail.com ( This mail is for customer / Buyer only ) And if you wants to add your hand as a supplier, And if you have volume manufacturing capacity of chemicals, pl. drop your mail at rxmarinechemical@gmail.com ( This mail is for supplier only )