Product Application
- 9007449 reads
Immersion Type Heat & water scale remover.
Testing chemicals required
Indicator solution :phenolphthalein
Testing solution : 0.1N sodium hydroxide solution
Method of control
Restore the volume of the tank to its original level, if necessary, by adding water. Thoroughly mix and take a sample of 50-100ml. After allowing to cool to ambient, pipette 25ml into a 250ml volumetric flask. Make up to the mark with distilled water. Pipette 10ml of this solution into an Erlenmeyer flask and add 5-10 drops of Indicator solution No.1. Titrate against Testing solution No.1 to a pink end-point. Record the volume used as (V).The bath strength is calculated as follows:
Strength (vol% ARDROX 14) = V x 1.4
Effects on materials
RXSOL 14 is inhibited against attack on steel. It will rapidly attack aluminium, zinc, magnesium and cadmium.
RX MARINE INTERNATIONAL is most popular chemicals source in INDIA, Keeping ready stock at 5 LOCATION which includes Mumbai, Kandla - Gandhidham, Vizag - Visakhapatnam, Ennore - Chennai, Kolkata more then 3000 types of chemicals. Please click here to get PRODUCT Categories details http://rxmarine.com/Products
Mail Us for any PRODUCT related information and purchase inquiry : rxmarinechemical@gmail.com ( This mail is for customer / Buyer only ) And if you wants to add your hand as a supplier, And if you have volume manufacturing capacity of chemicals, pl. drop your mail at rxmarinechemical@gmail.com ( This mail is for supplier only )