Product Dose
- 8782506 reads
Palladium chloride test for active surfaces:
Passive steel does not liberate Hydrogen form Sulphuric acid. Palladium can absorb 900 times its own volume of Hydrogen by Adsorbsion and Occlusion. Hydrogen gas reduces Palladium Chloride PdCl2 easily to form black Palladium metal and Hydrogen Chloride.
H2 + PdCl2 = Pd + 2 HCl
This is the reason that Sulphuric acid or HCl must be mixed with palladium chloride if the black precipitate of metal must be seen by the naked eye. Passive SS does not liberate hydrogen. Palladium Chloride results can be tested using a mass spectrometer too.
Rinse PdCl2 with DI water from a squirter as the black spot is active.
If free iron ( not oxidised iron ) is present on the SS surface the iron is oxidised by Palladium Chloride ( acid reagent solution ) to iron oxide.
4PdCl2 + 4 H2O + 3 Fe = 4 Pd + 8 HCl + Fe304
Palladium chloride comes in a small bottle with a dropper. The contact time should be 3 min minimum. The shelf life is one year if you keep it in the fridge in a coloured bottle.
we are also supplying it. Palladium chloride crystals or deliquiscent powder is soluble in water or alcohol.
RX MARINE INTERNATIONAL is most popular chemicals source in INDIA, Keeping ready stock at 5 LOCATION which includes Mumbai, Kandla - Gandhidham, Vizag - Visakhapatnam, Ennore - Chennai, Kolkata more then 3000 types of chemicals. Please click here to get PRODUCT Categories details http://rxmarine.com/Products
Mail Us for any PRODUCT related information and purchase inquiry : rxmarinechemical@gmail.com ( This mail is for customer / Buyer only ) And if you wants to add your hand as a supplier, And if you have volume manufacturing capacity of chemicals, pl. drop your mail at rxmarinechemical@gmail.com ( This mail is for supplier only )
Palladium Chloride Passivation Test Kit Manufacturer