Manual Cleaning
For manual cleaning of separator parts and machinery parts.Make a solution between 5-20% concentration depending on how dirty Tank and equipment to be cleaned is. Both oil and lime will be solved with time, let soak for at least 2 hours. After 2 hours the parts can be cleaned using by High Pressure Machine rinsing or brushing.
Cleaning In Place of Separator
For the lube oil separator use a 20% solution
For the fuel oil separator use a 10% solution
Recommended cleaning temperature is 70-90oC (158-194oF). A normal cleaning cycle is between 1 to 3 hours depending on the dirtiness and character. If the separator has very hard deposits the cleaning cycle may have to be repeated with new cleaning fluid.
Lube Oil Tank :
- Instead of recirculation cleaning the RXSOL Lube Oils Cleaner can injected into the Butter worth system . Kindly make the solution 0.5 -5% and inject same. Depending on the tank size and height fill the necessary amount of freshwater or seawater into the service tank .
- Butter worth all tanks to be cleaned 1-1,5 hour using the water from the service tank .
- Heat the water by means of heating coils, cargo heat exchanger or going via the Butter worth heater.
- The pre-cleaning temperature should be between 70 and 80°C.
- Pump the waste water from the tanks to be cleaned back to service tank (overtop).
RX MARINE INTERNATIONAL is most popular chemicals source in INDIA, Keeping ready stock at 5 LOCATION which includes Mumbai, Kandla - Gandhidham, Vizag - Visakhapatnam, Ennore - Chennai, Kolkata more then 3000 types of chemicals. Please click here to get PRODUCT Categories details http://rxmarine.com/Products
Mail Us for any PRODUCT related information and purchase inquiry : rxmarinechemical@gmail.com ( This mail is for customer / Buyer only ) And if you wants to add your hand as a supplier, And if you have volume manufacturing capacity of chemicals, pl. drop your mail at rxmarinechemical@gmail.com ( This mail is for supplier only )