Browse : A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z  
Featured Products 

Boiler Chemicals-42

Toluene AR grade

Product Description | Product Application | Product Notes| Product DOSE
Toluene, analar reagent grade For oil, water, Amine, Scale Composition tests metering operation. Packed in 2.5 Ltr Glass Bottle. Keeping ready stock - Mumbai, Kolkata, Chennai, Kandla, Vizag, Fujairah, Dubai, Middle East.
Code:
RXSOL-60-1201-500
Other Equivalent Brand

TOLUENE L.R.

Short Description:
For Industrial, Pharmaceutical, Flavor & Fragrance or Lab Use. And For oil, water, Amine, Scale Composition tests metering operation
Active Matter:
99.98
Toluene AR grade
Application:
  PRODUCT SPECIFICATIONS          LIMITS TYPICAL LOT ANALYSIS Assay (GC), min 99.7% 99.97% [+] Read More...
Using Procedure:
Not intended as an active substance in Food or Drug.  Not to be considered a Medical Device. Not intended for use as a Disinfectant as defined by the EPA. 
Note:
Toluene AR grade MSDS and Certificate of 2.5 L glass bottle available through email.
Technical Specifications:

Toluene is toxic if swallowed or inhaled. It is also harmful in contact with the skin. Toluene is very flammable, so presents a significant fire risk. There is some evidence that repeated exposure to toluene may cause reproductive harm.Toluene should be stored in a "non-chlorinated waste" container for subsequent disposal.Safety glasses. If gloves are required, polyvinyl alcohol is recommended.

Standard Packing :
4x1 gallon Fluorinated Poly,
4x4 liter Amber Glass,
5 gallon Metal w/Rieke Spout,
55 gallon New Metal Drum

 

 
4x1 gallon Fluorinated Poly, 4x4 liter Amber Glass, 5 gallon Metal w/Rieke Spout,
55 gallon New Metal Drum
Remarks:

Wear safety glasses. The working area must be well ventilated to prevent the build-up of toluene vapour. Make sure that any sources of ignition, such as Bunsen burners, hot plates and hot air guns, are removed before you start work.

Eye contact: Immediately flush the eye with plenty of water. Continue for at least ten minutes and call for medical help. Skin contact: Wash off with soap and water. Remove any contaminated clothing. If the skin reddens or appears damaged, call for medical aid. Note that clothes soaked in toluene will be very flammable, so should be removed in an area in which there is no risk that they might catch fire. If swallowed: Call for immediate medical help.

Toluene AR grade manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Toluene AR grade at a competitive price from us. We have ready stock of Toluene AR grade in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Toluene AR grade
Toluene AR grade
:
Packing Size:
2.50 Ltr.
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Hydrocarbon Remover Hcf

Product Description | Product Application | Product Notes| Product DOSE
Best cleaner for Zinc coated tanks  for removal of  traces  of HYDROCARBONS from tank,  after cleaning of TANKS from solvent base tank cleaning materials . when possibilities of next cargo will contamin [+] Read More...
Code:
RXSOL-20-2008-025
Other Equivalent Brand

NEUTRAL HCF, HYDROCARBON CLEANER, HCF CLEANER

Short Description:
HCF cleaner supplier in mumbai, jnpt, mundra, sikka, kandla, hazira, kolkata, haldia, ennore, paradip, manglore, kakinada, vizag visakhapatnam, ennore, chennai, krishanpatnam, Fujairah, Dubai, Sharajh Middle east.
Generic Name:
Neutral HCF degreaser for Tank Clean non ionic detergent with anti foam mixture
Did you Know?

 HCF Remover is solvent free emulsifier based Effective Tank Cleaner?

Information:

Neutral HCF supplier and stockist at all Indian and UAE - Middle East Coastal. HCF Neutral chemical importance is to emulsify vegetable oils and animal oils and fats residue with less foaming effect. Chemically if you can understand oil and fat which contain FATTY ACID while the general cleaner is alkaline in nature which is resulting greasy mass oncoming contact with Fatty Acid and Alkali cleaning material. To avoid the formation of GREASE like substance inside the tank, it is very important to take care of an alkaline cleaner with such cargo. On the other hand HCF Neutral ( free from any kinds of alkali mixture ) emulsifying oils particle and makes water soluble to remove from zinc-silicate coated tanks surface.

Active Matter:
89 - 94 %
Hydrocarbon Remover Hcf
Application:
A very strong low foaming cleaner, Especially formulated to soften up / remove baked on drying oils and also used after animal and vegetable oils, fish oils, tall oils, tung oil etc.  It is low toxic pr [+] Read More...
Using Procedure:
Using Procedure:- First of all flush the system with cold water to prevent evaporation rates and polymerization then the most economical method of using RXSOL-20-2008-HCF is by direct injection followed by r [+] Read More...
Note:
Tank Lining– Stainless / Epoxy / Phenolic / Zinc-silicate.
Technical Specifications:

Characteristics:

  • Removes grease, oil, carbon deposits, soil and grime.
  • Keeps loosened deposits in suspension preventing re-deposition.
  • Low toxic.  , Non-flammable.
  • Free from hydrocarbon solvents.
  • Effective and economical in use , Water-based cleaner.
  • RXSOL-20-2008 has numerous cleaning applications including removal of greases, waxes, oil, sludge, soot, carbon deposits and general dirt and grime.
  • Non-corrosive to ferrous metals.  Suitable for all tank-coatings.
  • Can be used for gas and hydrocarbon freeing of tanks.
  • Can be used for deodorizing
  • Contains wetting agents.

Note:- Completely miscible with sea water.

Neutral HCF Cleaner is free from solvent for removing all vegetable and animal fats and oils, and light mineral oils from ship tank surface. H.C.F. Cleaner effectively remove and emulsify residual contents of oil and sludge from cargo tanks H.C.F. Cleaner is a biodegradable, water soluble tank cleaner, containing special non-petroleum solvents and surfactants.

HCF Neutral Tank cleaner manufacturer and supplier in Mumbai, Mundra, Gandhidham, Chennai, Ennore, Visakhapatnam, Gangavaram, Kolkata Haldia, Paradip, Navlakhi Hazira, Dubai Sharjah Abudhabi, Ajman, Fujairah UAE Middle East, Muscat Sohar Oman, Kenya Mombasa, Uganda Jinja, Canada

Hydrocarbon Remover Hcf
:
Packing Size:
25.00 Ltr.
Available Packing Size:
HCF remover makes tank HYDROCARBON free, Available in 25, 50, 210 Ltrs DRUM.
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Boiler Coagulant

Product Description | Product Application | Product Notes| Product DOSE
RXSOL-50-5003-020 is a Liquid sludge conditioner designed to prevent deposits. A concentrated solution of surface-active polymers which is use as an internal sludge conditioners in boilers.
Code:
RXSOL-50-5003-020
Other Equivalent Brand

GREEN BC, liquid Coagulant, LC 102/A Nor Chem, Boiler Coagulant 20 Ltr

Short Description:
A concentrated solution of surface-active polymers which is use as an internal sludge conditioners in boilers. Boiler Coagulant prevents the formation of deposits on boiler internal surfaces.
Generic Name:
Sludge Conditionaer for Boiler
Active Matter:
55 - 58 %
Boiler Coagulant
Application:
RXSOL-50-5003-020 Boiler Coagulant prevents the formation of deposits on boiler internal surfaces. Sludge is kept dispersed in small particles and conditioned to be removed normal blow down. In this way tube over heating due to deposits is avoided. 
Using Procedure:
The initial dosage is 20 ml of treatment daily for every ton of boiler capacity. Bottom blow down is required daily when using Boiler Coagulant. For optimum results dose Boiler Coagulant directly to the bo [+] Read More...
Note:
Liquid product, easy to feed. Prevents the formation of adherent deposits and sledges in boilers. Keeps sludge dispersed for efficient removal by blow down. Keeps boilers clean and extends bo [+] Read More...
Technical Specifications:

Appearance

LIQUID

Color

AMBER

AMBER

9

Density

1.2

Remarks:

Boiler Coagulant manufacturer, supplier and exporter in Mumbai, Kandla, Kolkata, Howrah, Vishakhapatnam, Chennai, Tuticorin, India. Ready stock of boiler coagulant chemicals liquid in Fujairah, Muscat Barka Oman, Kenya, Uganda, Canada. Buy the best Boiler coagulant chemical from RXSOL brand.

A concentrated solution of surface-active polymers which is use as an internal sludge conditioners in boilersBoiler Coagulant prevents the formation of deposits on boiler internal surfaces. Sludge is kept dispersed in small particles and conditioned to be removed by normal blow down. In this way tube overheating due to deposits is avoided. 

Boiler Coagulant Sludge Conditioner Manufacturer and supplier in India UAE Oman Nairobi, Mumbai, Surat, Pune, MIDC, Gandhidham GIDC Gujrat, Kolkata, Haldia, Chennai, Ennore, Vizag Gangavaram, Paradip, Fujairah, Dubai, Sharjah, Abudhabi, Ajman, Sharjah, Middle East, UAE GUlf, Ruwi Ghala Barka, Sohar, Muscat Oman, Nairobi kenya, Canada

Boiler Coagulant
:
Packing Size:
20.00 Ltr.
Available Packing Size:
25 ltr., 210 ltr.
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Oxygen Control Corroision Inhibitor

Product Description | Product Application | Product Notes| Product DOSE
Code:
RXSOL-50-5007-025
Other Equivalent Brand

Oxygen ScaVenger, GREEN OC, Oxytreat-s, Eliminox 9-002, Eazy Safescav, Carbohydrazide Ox Scav Not Hydrazine, ROCHEM OXYTREAT, MAXTREAT 3100L, HYDRAZIDE, Aquatreat 660, Coroban 26

Short Description:
Catalyzed liquid oxygen scavenger, This formulation is especially effective way of protecting ferrous and aluminum metals from corrosion due to adverse environmental conditions such as high heat and humidity, seawater or other harsh environments , for b
Generic Name:
Oxygen Scavenger
Active Matter:
78-83%
Oxygen Control Corroision Inhibitor
Application:
Powder Application:- For average conditions the recommended dosage is 0.30 ounces (weight) per cubic foot (28 Liters) of enclosed space.( 300 g/cubic meter) Concentration can be increased to protect [+] Read More...
Using Procedure:
RXSOL-50-5007-025 The objective is to maintain a hydrazine residual between 0.05-0.2 ppm depending on operating pressure and boiler designe. Actual consumption is determined under operating conditions. A nor [+] Read More...
Note:
More about Water Boiler Treatment & Powder / liquid Inhibitors scales are very damaging to the boiler because they interfere with the heat transfer and can lead to overheating and eventually, boile [+] Read More...
Technical Specifications:

Products Properties:-

Non-Flammable
Safe Plant Handling
Low Odor
Provides corrosion protection in the liquid and the vapor phase
When used in hydrostatic testing the product provides protection in liquids below, above and at the liquid levels
Protection of recessed and hard to reach areas. Complicated valves and the interior surfaces of piping and equipment, which are often difficult or impossible to reach, are protected with true Vapor Corrosion Inhibitor action Easy to Useits POWDER  can be  applied by either blowing with conventional air blasting equipment or other methods using compressed air . Can be applied by sprinkling , rinsing or dipping metals in a solution of  RXSOL-50-5007-025 , hydrotest solution, metalworking fluids, coatings, adhesives and water treatment formulations.


 

Remarks:

RXSOL-50-5007-025 is a powerful oxygen scavenger in liquid sulphite form suitable for low and medium pressure boilers. The reaction of RXSOL-50-5007-025 with oxygen is catalysed ensuring the rapid absorption of oxygen to protect feedlines and boilers from corrosion

Oxygen Control Corroision Inhibitor - Boiler water treatment chemicals manufacturer and supplier in Mumbai, JNPT, Nhava SEVA, Kandla - Deen Dayal Upadhyay, Mundra, Surat, Manglore, Goa, Chennai - Ennore, Visakhapatnam - Gangavaram, Kolkata - Buz Buz, Haldia, Paradip, Fujairah, Dubai, Sharjah, Abu Dhabi, Oman.

Oxygen Control Corroision Inhibitor
:
Packing Size:
25.00 Ltr.
Available Packing Size:
25 ltr., 50, 210 ltr. packing of Oxygen Control Corroision Inhibitor available with us.
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Alkalinity Control

Product Description | Product Application | Product Notes| Product DOSE
RXSOL-50-5002-020 is a concentrated liquid alkaline product for corrosion and Calcium scale control in boilers.   Suitable for low-pressure boiler systems (0-32 bar), medium-pressure steam propulsion [+] Read More...
Code:
RXSOL-50-5002-020
Other Equivalent Brand

GREEN AC, Alka active liquid, GC Concentrated Alkaline Liq , GC, Alka Treat, ACT 100 NORCHEM, Alkaline Treatment Liquid 9-512, Eazy Neutralise, ALKATREAT, Sodium Hydroxide Alkali control, PH Neutraliser, Maxtreat-3004, 551442, Alkanity Control 20 Ltr

Short Description:
Concentrated liquid alkaline product for corrosion and Calcium scale control in boilers.
Generic Name:
Boiler Chemical to treat Water Alkalinity
Active Matter:
58 - 63%
Alkalinity Control
Application:
RXSOL-50-5002-020 provides the alkaline condition for hardness control to function correctly. Without the correct precipitation and subsequent blow down of hardness salt, scale would form. This would [+] Read More...
Using Procedure:
For optimum results dose RXSOL-50-5002-020 direct to the boiler with a RXSOL Boiler Water Treatment Dosing unit, or via the bypass pot- feeder installed in the boiler feed line. Required dosage can be cont [+] Read More...
Note:
It can also be used as a neutralizing agent following acid cleaning with  descaling materials ( RXSOL-11-1008--DC descaling Liq / RXSOL-54-1008-SA Safe Acid PWD )  CHARACTERISTICS Alkalinity balace m [+] Read More...
Technical Specifications:

Testing control procedure

  1. Test water sample from the water boiler as described in the direction of the  Alkalinity Test Kit ( p & m Total ) http://www.rxmarine.com/Alkalinity-test-kit
  2. Determine the present alkalinity value expressed as ppm CaCO3 .
  3. Desired level of 100-150 ppm as CaCO3.
  4. A control test for the alkalinity  of the water should be conducted after 3- 6 hours from the application.
  5.  
Remarks:


Mechanism: It converts calcium hardness into soft, non-adherent sludge that is easily removed by blowdown.

The presence of alkalinity in a water sample may be due to many different substances.  However, for the sake of simplicity, the presence of bicarbonate, carbonate, and hydroxide ions is commonly considered as alkalinity.  The points of change in colour of phenolphthalein and methyl orange indicators, which occur at pH 8.3 and pH 4.3 provide standard reference points which are almost universally used to express alkalinity.

Very high alkalinity values can be undesirable in an industrial water supply.  For example, the presence of a high methyl orange alkalinity should be avoided in boiler feed water because of the resultant carbon dioxide content of the steam.  Carbon dioxide usually is responsible for the corrosion of steam and return lines.  High boiler water alkalinities are also undesirable because the presence of high hydroxide ion concentration is the primary cause of caustic metal embrittlement. A very high boiler alkalinity can also lead to an undesirable carryover condition.  On the other hand, the alkalinity of boiler water must be sufficiently high to protect the boiler metal against acidic corrosion and to ensure precipitation of scale-forming salts.  Usual treatment approaches include setting both a minimum alkalinity level and an operating range.
 

Hydroxide alkalinity may be determined by adding barium chloride prior to titration to precipitate the carbonate ion from solution, allowing direct titration of the hydroxide alkalinity.  Measurement of hydroxide alkalinity is also used to control lime soda softeners.
 

In cooling water systems, alkalinity is of major importance since the total alkalinity of a water is one factor that must be considered when predicting the tendency for the water to precipitate calcium carbonate scale.  Depending on the choice of chemical treatments to protect against corrosion and scale formation, the operating alkalinity and pH ranges are chosen to balance these two features.

Alkalinity Titrimetric Method (0-200 ppm) 

Principle Theory

This test is based on the determination of alkalinity by titration with standard acid to the phenolphthalein colour change (or to a pH of 8.3) and to the methyl orange colour change (or a pH of 4.3).  For determination of hydroxide alkalinity only, barium chloride is added prior to titration to precipitate the carbonate ions.  Titration is then taken only to the phenolphthalein endpoint.  A pH meter may be used instead of the indicators to determine the endpoints of the titration.

Testing control procedure

  1. Test water sample from the water boiler as described in the direction of the  Alkalinity Test Kit ( p & m Total ) http://www.rxmarine.com/Alkalinity-test-kit
  2. Determine the present alkalinity value expressed as ppm CaCO3 .
  3. Desired level of 100-150 ppm as CaCO3.
  4. A control test for the alkalinity  of the water should be conducted after 3- 6 hours from the application.

CHARACTERISTICS

  • Alkalinity balace mechnism to control corrosion.
  • It converts calcium hardness into soft, non-adherent sludge that is easily removed by blowdown. Treated as good salt-scale controler product.
  • Compatible with other BOILER chemicals
  • Tested with long and continious running plant for more then 20 Years and easy to apply and use.
  • Avoid contact with any acidic / oily - FAT materials.

Alkalinity Control works as PH Neutrilizer in Boiler system. Alkalinity control one of important boilere water treatment chemicals which plays very important role by controlling corrosion and solid deposits in boiler system.

Alkalinity control makes sludge in soft form, which can be easily blown down from bottom side of BOILER.

Other valuable Boiler Water Treatment Chemical product :

RXSOL-50-5020-025 Boiler Water Treatment Auto
RXSOL-40-4091-025  Scale and Corrosion Inhibitor for Cooling Water
RXSOL-40-4009-025 MICRO BIOCIDE Cooling Water 
RXSOL-50-5002-025 Alkalinity Control 
RXSOL-40-2000-025 RXSOL 2000 corrosion inhibitor 
RXSOL-40-4009-025 MICRO BIOCIDE Cooling Water
RXSOL-50-5021-025  Hardness Control Liquid

Boiler Water Treatment Chemicals Alkalinity Control manufacturer and supplier in India UAE Oman, Alkalinity Control is most valuable Boiler water Treatment chemicals to converts calcium hardness into soft, non-adherent sludge that is easily removed by blowdown. Alkalinity controller boiler chemical manufacturer and supplier in Mumbai, Chennai, Kolkata, Visakhapatnam, Surat, Gandhidham, Chennai Ennore, Paradip, Nashisk, Pune, Varanashi, Patna, Tata, Ranchi, Fujairah, Sharjah, Ajman, Abudhabi, Dubai, UAE Gulf, Barka, Ruwi Ghala, Muscat Oman, Nairobi, Kenya, Canada

Alkalinity Control
:
Packing Size:
20.00 Ltr.
Available Packing Size:
25 ltr, 50, 210 ltr. This chemical is used to treat Boiler Water Alkalinity.
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Tank Degreaser Heavy Duty

Product Description | Product Application | Product Notes| Product DOSE
RXSOL Solvent-based tank cleaners is highly effective to remove tough residues. Concentrated effective cleaner for contaminated FUEL OIL, cargo tanks. It's high emulsification formula easily react wit [+] Read More...
Code:
RXSOL-20-2029-020
Other Equivalent Brand

Tank Cleaner - A, Tank Degresol A Heavy Duty 20 Ltr

Short Description:
RXSOL Solvent-based tank cleaners is highly effective to remove tough residues.
Generic Name:
Solvent Based Emulsifier cum Heavy duty Tank Cleaner
Tank Degreaser Heavy Duty
Application:
RXSOL Solvent-based tank cleaners is specialized to clean and dissolve most stubborn residues of oil, grease, and other contaminants from tanks and other industrial equipment. These cleaners are typic [+] Read More...
Using Procedure:
For tank cleaning 0.05% to 0.5% , Non corrosive . It may safely be applied on all metal surfaces .
Note:
Technical Specifications:

Remarks:
RXSOL Solvent based tank cleaner must be use in a opne and well-ventilated area and to follow all safety precautions and guidelines.

#Tankcleaner_Supplier
#Tankcleaner_Manufacturer
#Tankcleaner_KandlaMUNDRAJamnagar
#Tankcleaner_MumbaiKOLKATAchennai
#Tankcleaner_Visakhapatnam
 

Tank Lining – Stainless / Zinc / Epoxy / Phenolic.
Using-Procedure    

Spraying This can be beneficial as part of the initial cleaning process after the carriage of Lube oils and Lube oil additives.  As soon as the tank in question has been checked empty by the attending surveyor, RXSOL-20-2029-020 Plus should be sprayed over all surfaces which are safely reacheable.
Portable machines – After 45 minutes the butterworth machines should be operated for 3 x 20 minutes drops using warm 60o C, then the machines brought back to the top and a full hot wash 80 – 85 o C should be carried out for at least 6 hours.
Fixed machines – Wash ambient for 45 minutes followed by warm water for one cycle before increasing to hot (80oC) for 4 hours.
Injection  – This can be carried out by injecting RXSOL-20-2029-020 Plus into the butterworth system after the heater.  A normal amount to use would be 100 – 150 liters during the initial washing cycle.  Water temperature should be 60o C during the injection period then brought up to 80 – 85 o C for the full washing period.
Re-circulation

– Possibly the best result are achieved by re-circulating a solution of RXSOL-20-2029-020 Plus after the initial rough washing of the tank.  A sufficient amount of fresh water to maintain good suction should be heated  to 60 o C and approximately 420 liters of RXSOL-20-2029-020  Plus (2 drums) added for each 500 liters of fresh water.  The temperature of the mixture can be increased depending upon  the melting point if the product being cleaned.  The solution should be circulated for at least 4 hours and the butterworth machines operated at maximum pressure in all areas of the tank  throughout this process.  If a number of tanks are to be circulated, then a substantial quantity of solution can be made so that transfers can be made without delay and any small amounts lost will not affect the operation.  Normally following transfer to another tank, 100 liters RXSOL-20-2029-020 Plus is added for each 5000 liters of solution.  This is called “spiking”.

Tank Cleaner Heavy Dutry Solvent Emulsifier based product and specified marine chemical tank cleaner category msnufscturer and supplier in Ruwi Ghala Barka Muscat Sohar Oman, Fujairah, Sharjah, Ajman, Abudhabi, Dubai, UAE Gulf, Fujairah Tank Terminal, Gulf, Mumbai, JNPT, Masjid Bunder Yellowgate Mumbai, Gandhidham Kandla Mundra, Jamnagar, Hazira, Haldia Buz Buz Kolkata Paradip, Visakhapatnam, Gangavaram, Ennore Chennia, Kakinada, Nairobi Kenya Sudan Yemen


Tank Degreaser Heavy Duty
:
Packing Size:
20.00 Ltr.
Available Packing Size:
Solvent Emulsifier Based Tankcleaner contains an advanced surfactant, Its high emulsification formula easily reacts with residue/sludge deposits. Available in 25, 50, 210 Ltr PACK.
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Soot Remover Powder

Product Description | Product Application | Product Notes| Product DOSE
RXSOL-70-7005-025 is a dry powder compound formulated for safe removal of soot and deposits from boilers and diesel engine exhaust systems.
Code:
RXSOL-70-7005-025
Other Equivalent Brand

LT-Soot Release, Caretreat Soot, Soot Cleaner, Soot remover powder 25 Kg, Easy Soot remover-P, Rochemite Powder

Short Description:
Dry powder compound formulated for safe removal of soot and deposits from boilers and diesel engine exhaust systems.
Generic Name:
Boiler and Diesel engine exhaust cleaner
Active Matter:
98 - 99%
Soot Remover Powder
Application:
If deposits are allowed to form on heat exchangers, the loss of efficiency can be directly related to extra fuel consumption. A 1 mm deposit is approximately equivalent to a 10 % efficiency loss, a 3 [+] Read More...
Using Procedure:
Directions for Use and Dose Rates Soot Remover should be introduced to the boiler through a suitable port, preferably with a blower, ensuring that the powder is spread through the flame path towards the bac [+] Read More...
Note:
Technical Specifications:

Soot Remover Chemicals manufacturer and supplier in Mumbai, Kandla, Kolkata, Chennai, Visakhapatnam, Surat, Ajman, Fujairah, Dubai, Abudhabi, Gulf Abudhabi, Barka Muscat Sohar, OMan, Nairobi Kenya, Africa, Canada

Soot Remover Powder
Soot Remover Powder
Soot Remover Powder
:
Packing Size:
25.00 Kg.PWD
Article News:
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Hardness Control Boiler Treatment

Product Description | Product Application | Product Notes| Product DOSE
Hardness Control is a white dry powder Phosphate Boiler Water Treatment product used for the reduction of hardness in boilers. Hardness Control is highly soluble in water and It will precipitate calcium hardness as a non-adherent sludge.
Code:
RXSOL-50-5006-020
Other Equivalent Brand

Boiler Water Treatment Hardness Control, Green HC, Boiler Water Treatment Phosphate Control 20 Kg

Short Description:
Phosphate Boiler Water Treatment Hardness Control is a white dry powder Phosphate Boiler Water Treatment product used for the reduction of hardness in boilers. Hardness Control is highly soluble in water and It will precipitate calcium hardness as a non-a
Generic Name:
Boilere Water Treatment for Hardness Control
IMPA Code:
551441
Hardness Control Boiler Treatment
Application:
Hardness Control is formulated to form a precipitate with calcium ions which will not adhere to metal surfaces but are in a form suitable for blowdown. Used for boilers and water softening.
Using Procedure:
For optimum results dose Hardness Control direct to the boiler via the bypass pot-feeder. The dry powder should be dissolved in hot water (50°C) at a ratio of 1 part powder to twenty parts condensate (e.g. 500 grams/10 litres). Ensure that treatment is fully dissolved before dosing.
Note:
This  treatment dosed at 1.49 grams per ton of distilled water provides 1.0 ppm phosphate. Feed Points: Dose with other BOILER CHEMICAL /  alkaline liquid by diluting withcondensate and feed directly into [+] Read More...
Technical Specifications:

Sampling And Testing

A sample of boiler water should be drawn for analysis daily. The sample should always be taken from the same point after blow down, cooled and tested immediately. Follow the Rxsol Hardness Test Kit instructions and fill the Boiler Water Log Form according to result results. It is important that regular testing is carried out to ensure levels of treatment are correct.

Physical Properties :

Appearance        :White powder
Corrosive action  : non
pH 1% solution   : 8,8
Flash point         : none

Remarks:

A precipitant designed to elimate scale deposits and lower the hardness of water in boilers with working pressure up to 60 bars.

It is used in conjunction with alkaline liquid to prevent calcium scale deposits. Both products are used in our standard boiler water treatment programs for low-pressure boiler systems (0-32 bar) and medium-pressure steam propulsion vessels (32-60 bar).

Benefit and Features

  • Highly active phosphate based compound, economical in use.
  • Easily dissolved in water for dosing.
  • Scale problems due to calcium are eliminated.
  • Maintains sludge in a non-adherent state for ease of blow down.
  • Simple test to determine level of treatment.
  • Can be used for boilers of all pressures.
    Rxsol Hardness Control does not influence the alkalinity in the system

Hardness Control 20 Kgs manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Hardness Control 20 Kgs at a competitive price from us. We have ready stock of Hardness Control 20 Kgs in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Hardness Control Boiler Treatment
Hardness Control Boiler Treatment
Hardness Control Boiler Treatment
:
Packing Size:
20.00 Kg.PWD
Available Packing Size:

25

HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Combotreat Boiler Chemical

Product Description | Product Application | Product Notes| Product DOSE
RXSOL-50-5004-007 is a dry powder containing Alkalinity builders, Phosphates and Sludge Conditioners. Product Description:-RXSOL-50-5004-007  is a well-balanced blend of several powder for boiler water treatment, resulting in a scale and corrosion control by one simple operation.
Code:
RXSOL-50-5004-007
Other Equivalent Brand

BOILER WATER TREATMENT, Combotreat PWD 7 Kg

Short Description:
A well-balanced blend of several powder for boiler water treatment, resulting in a scale and corrosion control by one simple operation.Dry powder containing Alkalinity builders, Phosphates and Sludge Conditioners.
Generic Name:
Boiler Water Treatment Chemical Powder
Active Matter:
55 - 58%
Combotreat Boiler Chemical
Application:
The correct level of alkalinity ensures that optimum conditions exist for : Precipitation of hardness salts in conjunction with phosphate. Neutralization of acidic conditions. Avoidance of caustic c [+] Read More...
Using Procedure:
RXSOL-50-5004-007 is best dosed by means of a bypass pot feeder directly into the boiler feed line.   RXSOL-50-5004-007 is strongly alkaline. RXSOL-50-5004-007  is best applied diluted with WATER ,  any [+] Read More...
Note:
Characteristics:- • Convenient treatment, which provides the basic alkalinity on which successful water treatment depends. • Provides optimum conditions for hardness control to function. • Neutralizes a [+] Read More...
Technical Specifications:

Control Procedure:-Control is by simple  boiler water tests or RX CLEANSERS  can provide a suitable test  kits for this purpose
 

Appearance

Clear  liquid   

Solubility In Water

Complete 

pH (1 Vol %)     

-13   

Compability

 

Metal       

Corrosive to aluminium, magnesium, zinc and tin.   

Rubber

No known effect.   

Packaging

Product Size (in Kg )



 

Remarks:

Packaging, Handling, First Aid & Storage:-RXSOL-50-5004-007  is generally supplied in drums containing 25 Kg/50 Kg barrel . Avoid contact with skin and eyes wear goggles & PVC gloves when handling. Keep an eye wash bottle close to the point of use. Do not take internally.On contact with Skin/Cloth, wash immediately with cupious amount of water. If eyes are affected they should be washed with water for at least 15 Minutes and medical attention sought immediately. If swallowed do not induces vomiting give plenty of water and call doctor immediately.
                                               

                                                                    **Keep drums tightly closed when not in use.**

Funtion Mechanism:-

Alkalinity Control:-This components of  RXSOL-50-5004-007  chemically  precipitate  the hardness of salts like Calcium & Magnesium & neutralizes the acidic conditions.
Hardness Control:-RXSOL-50-5004-007 provides phosphate reserve  to effectively  react with  and precipitate the hardness salts introduces with the feed water.
Sludge Conditioner:-RXSOL-50-5004-007 component  will preventing the sludge from  adhering to metals surfaces. Boiler sludge can only be removed by blow down.
Oxygen Scavanger:-Catalyzed  of  RXSOL-50-5004-007    controls  the formation of  oxygen to protects boiler & steam line corrosion protection. As an  additional benefits it will assist to neutralize dissolved carbon dioxide. In this way  RXSOL-50-5004-007  preventing oxygen “Pitting” corrosion.



Combotreat Pwd 7 Kg manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Combotreat Pwd 7 Kg at a competitive price from us. We have ready stock of Combotreat Pwd 7 Kg in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Marine Chemicals covers full range of ship maintenance and cleaning chemicals. RX MARINE INTERNATIONAL is one of largest share market holder of marine chemicals in India and UAE. We have more then thousends of marine chemical's customer world wide, Our product range of marine chemicals covers full range of ship Hold cleaning,  Ship Tank Cleaning, Ballast water tank treatment as well as its cleaning chemicals. And many more marine chemicals also covers full range of water treatment chemicals including Boiler water and cooling water treatment chemicals.
Our valuable marine chemicals classified links are given below :::

Ballast Tank cleaning and treatment chemicals :      http://rxmarine.com/BallastTank/treatment/chemicals

Cargo Bulk Ship Hold cleaning chemicals including slip coat :   http://rxmarine.com/HoldSolution-22

Tank Cleaning marine chemicals                      :      http://rxmarine.com/TankCleaner-20

Boiler Water Treatment marine chemicals         :     http://rxmarine.com/catalog/137

Cooling Water Treatment marine Chemicals      :     http://rxmarine.com/catalog/138

Deck Cabin Galley Maintenance Chemicals        :    http://rxmarine.com/Deck/Engine/Rigs/OilField/Chemicals

Degreaser                                                     :    http://rxmarine.com/Degreaser/moya/general/bilge/coldwash

Drain Cleaner  several types                           :     http://rxmarine.com/catalog/132

Electrical Parts / Motor Cleaning chemicals       :    http://rxmarine.com/catalog/133

Engine Maintenance cleaning marine chemical  :    http://rxmarine.com/catalog/134

Evaporator Treatment Chemicals                     :    http://rxmarine.com/EvaporatorTreat-51

Floor Cleaning / Polish                                   :    http://rxmarine.com/FloorCare/clenaer/polish/disinfectant/stripper/stain/rx

Fuel Oil Treatment marine Chemical                :    http://rxmarine.com/FuelTreatment-70

Hand Cleaning Paste / Other cleaner               :    http://rxmarine.com/HandWash/Personalcare-14

Oil Spill dispersant / Cleaning marine chem      :   http://rxmarine.com/OilSpillChemAccessory-17

Paint Cleaner / Remover                                :   http://rxmarine.com/PaintPrintcleaner/solvent-18

RO ( Reverse Osmosis ) Chemicals                  :   http://rxmarine.com/ROChemicals-33

Rust Cleaning Chemicals                                :   http://rxmarine.com/catalog/131

Scale Remover / Descaling Chemicals              :   http://rxmarine.com/ScaleRemover-11

Seawage Treatment Chemicals                       :   http://rxmarine.com/CoolingWater/Treatment

Test Kit  for Boiler Water / Cooling / Sewage   :   http://rxmarine.com/TestKit-62

Wall Wash Test Kit and Other reagent             :   http://rxmarine.com/WallWashTestKit-63

Rigs Oil field Chemicals                                 :   http://rxmarine.com/catalog/120

And we are keeping more then 3000 products at our various loaction and branches, Pl. share this link http://rxmarine.com/Products  .  Our product covers latest research and formulation as we run our marine chemicals division since 1995 under powerful and top notch leadership. We always providing our customer best value of product to reduce there expances for cleaing and maintenance. Our average sale of marine chemicals everyday is 18000 Ltr, Its everyday consumption among our customer always givng new direction to maintain best product in the market.

Email :  mail@rxmarine.com

Combotreat Boiler Chemical
:
Packing Size:
7.00 Kg.PWD
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Potable Water Test Kit

Product Description | Product Application | Product Notes| Product DOSE
RXSOL POTABLE WATER TEST KIT is a monitoring kit enabling shipboard personnel to regularly test the drinking water onboard to help determine whether it is suitable for drinking. The Convention require [+] Read More...
Code:
RXSOL-62-6538-001
Other Equivalent Brand

Drinking water test kit

Short Description:
RXSOL POTABLE WATER TEST KIT is a monitoring kit enabling shipboard personnel to regularly test the drinking water onboard to help determine whether it is suitable for drinking.
Generic Name:
Potable Water Test Kit
Information:

Potable Test Kit supplier in Mumbai, Kolkata - Haldia, Buz buj, Vizag - Visakhapatnam, Gangavram, Chennai - Ennore, Gandhidham - Kandla Mundra. Potable test Kit available for our regular customer with 50% owner discount. Our test kit easily available with all Indian shipping agent and shipchandler.  RXSOL Potable Water Test Kit range very easy to handle by any staff easiest compliant Marine Potable Water Testing Kit enables ships staff to monitor the quality of the drinking water on board the ship. 

Potable Water Test Kit
Application:
RXSOL POTABLE WATER TEST KIT is used for testing potable water, whether supplied from shore side or produced onboard. It is recommended that potable water be tested weekly, (or as may be required by t [+] Read More...
Using Procedure:
RXSOL POTABLE WATER TEST KIT contains everything needed to monitor the drinking water onboard in accordance with WHO guidelines. The kit measures pH, free and total chlorine, plus total coliforms and E.coli [+] Read More...
Note:
  Features • pH Tester and Buffer Kit • Chlorine Ampoule Test Kit, including color comparator • Coliform Test Kit, including UV lamp and safety goggles • Convenient C [+] Read More...
Technical Specifications:

Test Kit Contents

RXSOL POTABLE WATER TEST KIT -

pH Test Kit complete set along with Buffer Solution.
Chlorine Test Kit  Complete Set with Color Comperator.
Coliform Test Kit DA (Dechlorinating Agent) Complete et.

Remarks:

1.      Portable Water Quality Testing kit:- Designed to carry out more than six basic tests to measure the quality of drinking water quality – turbidity, free – chlorine, total chlorine, pH, color, microbiological and temperature tests; kit should include start- upreagents; kit to be potable and suitable for field ; with 44o C incubator chamber for analysis of faecal coliforms , internal battery, sealed within the case housing, which can be re-charged from mains or a car battery; membrane filtration unit using 47mm – 0.45mm pore size membrane filters; with basic incubator in pelican case, Turbidity tube; Colorimeter; Sterile Pastuer Pipettes (3ml) for easy transfer of media x10, filter funnel, aluminium gasket, bronze discs x2, 3 sets of 16 petri dises, O- ring x2; complete kit weight:10 kg, Dimension: 34.4cm X 16.4cm X 29.7cm,

2.      Free- chlorine Reagent:-  100 tests pack for use with free- chlorine testing equipment provided water quality testing.

3.      pH Reagent:- Reagent suitable for 100 tests pack for use with pH testing equipment provided in potable water quality testing kit.

4.      Electric Autoclave (4L Capacity):- Steam sterilizer autoclave; made of high quality aluminium / stainless steel fixed with safety valves; fitted with pressure and temperature indicator, pressure valves; maximum pressure: 0.1MPa; maximum temperature: 125o C.

5.      De- ion Pack:- De- ionizer pack cable of producing 5 liters of de- ionized water.

6.      Media for Microbiological Testing:- To be membrane lauryl sulphate broth; To be used in the potable water quality testing  kit for bacteriological analysis; with minimum if one year shelf life; Membrane filtration culture medium for the enumeration of coliform organisms and E. Coil in water and sewage samples; dehydrated culture medium; 500 g per bottle or container.

7.      Absorbent Pads And Membranes: To be used in microbiological water quality testing incubator; 0.45pm; 47mm; Sterile, white and gridded; Round for microbiological petri 47mm diameter; Minimum of 100 pieces per rack;.

8.      Pure White Vinegar ( Acetic acid, 5% concentration by volume) 500ml: Clear Colorless solution; wt./ml at 20o C : 1.047-1.052g: Freezing point: Not below 15.5o C: Non-volatile matter. <0.01%; Chloride (cl): <0.0005%; Sulphate(SO4): <0.0005%; Arsenic(AS):<0.0002%; Iron(Fe):<0.0002%;  lead (Pb): <0.0002%.

9.      Methanol for Alcohol Burner: Clear colorless, Assay (min):99.5%, Wt./ml at 20o C: 0.790-0.793, Refractive index: 1.328-1.331, Non-volatile matter; <0.005%, Aldehydes & Ketones [{(CH3)2 CO}]; <0.1%, Water:<0.25%.

10.   Electrical Conductivity Meter: Measuring rang 0.9999us, Temperature range 0-80o C, Resolution 1ps, Accuracy -+ 25, ATC: Yes, Battery life; 2 years, Auto-off; After 5 minutes, Dimension: 15cm (L) x 2.5cm (W) x 1.3cm(H), Power supply; DC 4 X 1.5V, Water- resistant, Magnetic housing, measures electrical conductivity and temperature, digital calibration, weight; 51g, Hold function to save measurement for convenient reading, include conductivity chart sticker on the back of the meter to explain values.

11.   TDS Water Quality Tester:- Measuring rang: 0-9999 (mg/l), Accuracy: -+ 2% F.S. resolution: 1ppm (mg/l), Display: 4-digital LCD, Environment humidity: <95%, Automatic  temperature: 0-50o C, Power Supply: 4X1.5V, Dimension: 165mm(L) X 26mm(H), Weight: 63g, Hold Function to save measurement for convenient reading, Easy to operate, Reliable and stable, Easy to Carry, Includes TDS chart sticker on the back of the meter that explain TDS valued.

12.   pH Water Quality Testers:- Potable micro-processor base pH/Mv/C  meter, pH working range of 0-14, Automatic temperature compensation facility 0o -50o, Resolution: 0.001pH – 0.1o, Powder supply: 4x1.5V, Dimension: 170mm (L)x 36mm (W)x 23mm(H), Weight: 91g, Easy-to-read custom dual-level LCD, on-the-spot measurement, stability indicator, hold function to save measurement for convenient reading, include pH chart sticker on the back of the meter that explain pH values, enclosed in heavy duty plastic carry case.

13.   Dissolved Oxygen Meter with Probes: To be microprocessor based portable dissolved oxygen (DO) meter of range 0.00-45.00 ppm(mg/l), DO range 0.01 ppm (mg/l) with features, two stage DO automatic calibration, auto-end point detection and compensation for temperature, salinity and altitude, attached with polarographic probe, PTFE membrane caps, electrolyte fill solution, Rugged carrying case associated NiMH battery. Galvanic probe eliminates polarization delay and delivers quick stable response complete with: Galvanic dissolved oxygen probe (1 meter), Assemble membrane cap housing (1), refilling electrolyte, carrying case and appropriate NiMH battery.

14.   BOD/Microbiological Incubator: BOD incubator unit internal temperature display; with the following feature; temperature range from 3-50o C, 2X internal socket, 9 liter internal volume, 2X shelves, with electronic thermo regulation system, Auto tuning, Power Supply: 240 Volts/50-60 Hz, temperature tolerance accuracy: -+0.5o C at 20o C.

15.   Manometric BOD Trak apparatus (0-700mg/l):Manometric BOD (Biochemical Oxygen Demand) trak apparatus, auto-switching power supply, selectable range 0-35, 0-70, 0-350 or 0-700mg/l BOD, capable of handling 6X 300ml amber glass bottles, supplied with six bottles, BOD Nutrient Buffer pillow, grease stopcock tube, incubator, potassium/lithium hydroxide powder pillow, six magnetic stir bars, spatula scoop, power rating 240V and cords.

16.   Respirometric BOD Nutrient Buffer Pillows 300ml, 50 per pack: To be used with BOD Trak apparatus for BOD testing.

17.   Potassium Hydroxide Reagent:- To be used with BOD Trak apparatus BOD testing, 25g per pack.

18.   Suspended solids meter with probes:- Microprocessor digital display TSS meter with probes, infra red diode system and beam focusing, wavelength 960nm, measurement ranges for turbidity and suspended solids are 0.001-9999 FNU and 0.001-400g/l respectively, air bubble compensation ability, sensor ranger 0-200 to 0-20,000mg/l auto-ranging, power supply rechargeable battery, operating sensor 0-60oC.

19.   COD Dry Thermostat Reactor Block with digital display: Signal block COD, dry thermostat, digital reactor block with 9 vials X 16mm, 2 X 20mm vial wells, power requirement 240 VAC, pre-programmed temperature range from 20 to 150 degrees in minutes, frequency Hz 50-60,supplied with 20>16mm reducing adaptor.

20.   COD colorimeter: Spectrometer based operated COD Meter, with wavelength range 420nm tp 600nm, to be supplied with sample cells COD/TNT adaptor and Nimh batteries, optical system 0/180 degrees transmittance, photometric measuring range 0.2 Abs,  spectral bandwidth 15nm filter bandwidth, automatic wavelength selection ability.

21.   COD Vials Rack: To be stainless steel rack for holding COD vials and test ‘N tube vials, holding min. capacity of 10 vials.

22.   COD Digestion Solution (0-150ppm):Low range chemical Oxygen Demand (COD) reagent for reactor digestion method range 1-150mg/l COD, Pack of 25 vials, EPA approved.

23.   COD Digestion Solution (0-1500ppm):High range chemical Oxygen Demand (COD) reagent for reactor digestion method. Range 1-1500mg/l COD, Pack of 25 vials, EPA approved.

24.   Disposable Transfer Pipette, 2ml: Low density polyethylene disposable pipette, 2ml. Packet of 500 pieces.

25.   Tensette Pipette:- Tensette Pipette, 0.1-1.0ml, with two step of pipette tips with 0.1 increment.

26.   Tensette Pipette: Tensette Pipette, 1-2ml, with two set of pipette tip with 1ml increment.

27.   Serological Pipette: High grade polystryrene serological pipettes of with 1/10 graduation, 50 per pack.

28.   Laboratory Plastic beakers: Clear plastic laboratory breaker, 250ml.

29.   Hand gloves: disposable Vinyl powder free gloves, latex-free gloves, XL size packet, 100 per packet.

30.   Laboratory plastic beakers: Clear plastic polypropylene PP measuring jar with spout, 500 ml.

31.   Laboratory plastic beakers: Clear plastic polypropylene PP measuring graduated cylinder with base, 250 ml.

32.   Water Sampling Bag; To be made of highly resistant FDA-Approved polyethylene. Maximum bag mouth opening to facilitate the insertion of water sample. Convenient write-on strip and volume marking s for measurements. 100mil capacity, transparent, thickness: 0.057mm, 100 pcs per box.

33.   Portable insulated thermal Cooler: To be made of oxford cloth and thin foil. Durable, waterproof and insulated. Handle design, easy to carry and convenient to use. A layer of thermal insulation material inside the bag. Bag to have heat preservation, coldand fresh function. Perfect to transport water sample cold. Perfect in preserving coldness inside the bag. Colour: Blue, Size: 30cmLx30cmWx20cmH.

potable water testing on ships
portable water testing equipment
RXSOL cooling water test kit
marine potable water test kit
RXSOL potable water test kit
RXSOL boiler water test kit
potable water test kit-c
drinking water standards test kit

POTABLE WATER TEST KIT manufacturer and supplier in India - Mumbai, Kandla, Chennai, Kolkata, Visakhapatnam, Gandhidham, Haldia, Paradip, Oman Sohar, Muscat, Barka, UAE Middle East Dubai, Sharjah, Ajman, Abudhabi, Gulf, Canada

Potable Water Test Kit
:
Packing Size:
1.00 Full SET

RX MARINE INTERNATIONAL is most popular chemicals source in INDIA, Keeping ready stock at 5 LOCATION which includes Mumbai, Kandla - Gandhidham, Vizag - Visakhapatnam, Ennore - Chennai, Kolkata more then 3000 types of chemicals. Please click here to get PRODUCT Categories details http://rxmarine.com/Products

 

Mail Us for any PRODUCT related information and purchase inquiry : rxmarinechemical@gmail.com ( This mail is for customer / Buyer only ) And if you wants to add your hand as a supplier, And if you have volume manufacturing capacity of chemicals, pl. drop your mail at rxmarinechemical@gmail.com ( This mail is for supplier only )

 

 

Syndicate content